TM 5-4210-249-13&P-1
0023-3
DRAFT
0023
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Perform Steps (8) and (9) if/when driver’s main inlet needs to be primed.
Priming the driver’s main inlet allows pumping operation to continue uninterrupted by
pumping water from a draft when original pumping operations started from onboard water
tank.
Valve is completely closed when red indicator light illuminates.
8.
Push DRIVER MAIN INLET valve control CLOSE button (6) until red indicator light (7) illuminates.
9.
Push DRIVER MAIN INLET PRIMER switch (8) to prime driver main inlet.
NOTE
Perform Step (10) if driver’s main inlet primer solenoid fails.
10. Pull MANUAL PRIMER handle (9) and push DRIVER MAIN INLET PRIMER switch (8).