TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 495 of 1188

TM 5-4210-249-13&P-1
0083-1
DRAFT
0083
FIELD LEVEL MAINTENANCE
WATER PUMP ENGINE PRESSURE GOVERNOR CONTROL PANEL PSI
PRESET CONTROL DOES NOT OPERATE
INITIAL SETUP:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WATER PUMP ENGINE PRESSURE GOVERNOR CONTROL PANEL PSI PRESET CONTROL DOES NOT
OPERATE
NOTE
Preset value for the pump operator’s panel pressure governor control is set by
manufacturer to 125 psi (862 kPa).
Step 1.
Start water pump engine (WP 0022).
Operate pump operator’s panel pressure
governor in PSI mode (WP 0024).
Press PRESET switch (WP 0004).
Check if water
pump pressure increases to preset value.
If water pump pressure does not increase to preset value, go to Step 4.
NOTE
Preset value for the pump operator’s panel pressure governor control is set by
manufacturer to 225 psi (1,551 kPa).
Step 2.
Operate personnel cab pressure governor in PSI mode (WP 0024).
Press PRESET
switch (WP 0004).
Check if water pump pressure increases to preset value.
If water pump pressure increases to preset parameter, fault corrected.
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
References
WP 0004
WP 0022
WP 0024
WP 0078
WP 0193
Equipment Conditions
Water pump engine OFF (WP 0022)
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)


Back to Top