TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 566 of 1188

TM 5-4210-249-13&P-1
0094-20
DRAFT
0094
TFFT3726
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 26.
Turn battery disconnect switch to OFF position (WP 0007).
While an assistant holds
pump operator’s panel FOAM SYSTEM switch to ON position (WP 0004), check for
continuity across FOAM SYSTEM switch from terminal wire 2816 (red) to terminal wire
2830 (red).
If there is no continuity, replace pump operator’s panel FOAM SYSTEM
switch (WP 0330).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top