TM 5-4210-249-13&P-1
0095-5
DRAFT
0095
TFFT04037
Step 9.
Turn battery disconnect switch to OFF position (WP 0007).
Disconnect cab pump
control wire harness cab power distribution wire harness connector.
With a test lead
set, check for continuity across cab power distribution wire harness wire 2842 (red)
from cab pump control wire harness cab power distribution wire harness connector,
terminal 7 to cab power distribution block relay 5, terminals 1 or 5.
a.
If there is continuity, repair wire 2842 in cab pump control wire harness
if repairable (TM 9-2320-325-14&P), or replace cab pump control wire
harness (WP 0443).
b.
If there is no continuity, repair wire 2842 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION