TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 686 of 1188

TM 5-4210-249-13&P-1
0102-2
DRAFT
0102
TFFT02571
Step 1.
Turn battery disconnect switch to ON position (WP 0007).
Open pump operator’s panel
cover (WP 0019).
Check if cab and pump operator’s panel FOAM A LEVEL gauge
indicators illuminate or flash (WP 0004).
If cab and pump operator’s panel FOAM A LEVEL gauge indicators do not
illuminate or flash, go to Step 9.
Step 2.
Check if only pump operator’s panel FOAM A LEVEL gauge indicators illuminate or
flash (WP 0004).
If cab FOAM A LEVEL gauge indicators do not illuminate or flash, go to Step
6.
Step 3.
With foam tank filled (WP 0031), check if cab and pump operator’s panel FOAM A
LEVEL gauges show equal readings (WP 0004).
If cab and pump operator’s panel FOAM A LEVEL gauges do not show
equal readings, go to Step 8.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top