TM 5-4210-249-13&P-1
0108-3
DRAFT
0108
TFFT03852
NOTE
Valve operation can be checked by noting vibration of valve assembly or by observing
rotation of 7/16 in. hex at end of valve drive assembly worm gearshaft.
Do not remove hose from driver side pre-connect B connector.
Water may be released
from system when valve is operated.
Step 2.
Remove pump house panel G (WP 0540).
While an assistant pushes pump operator’s
panel DRIVER SIDE PRE-CONNECT B valve control OPEN and CLOSE
buttons (WP 0004), check if driver side pre-connect B valve operates to open and close
positions.
If driver side pre-connect B valve does not open and close, go to Step 9
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION