TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 1075 of 1452

TM 5-4210-249-13&P-2
0219-43
DRAFT
0219
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8.
Install two hoses (84) on elbows (85).
NOTE
Install cable ties as required.
9.
Connect connector (83).
NOTE
Route cable as noted prior to removal.
10. Install cable (80) on stud (81) and engine (82) with nut (79) and cap (78).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
11. Apply electrical sealant to end of cable (80).
12. Install fuel return line (76) on fitting (77) with clamp (75).
13. Close door (74).
TFFT01543
WARNING
ICON 30, 44, 27


Back to Top