Step 62.
Remove diode block from cab power distribution block (WP 0399).
Install a jumperwire
between diode block terminals wire 1592 (gray) and wire 1609 (gray).
With rear
compartment doors open, check for continuity between wire 1592 (gray) cab instrument
panel wire harness connector, terminal 11 and a known good ground.
If there is continuity, replace diode block (WP 0399).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION