2.
Remove water pump gear case oil level check plug (3) from fitting (4).
3.
Remove water pump gear case oil drain plug (5) from fitting (6).
4.
Drain oil from two fittings (4) and (6) until oil stops draining.
5.
Install water pump gear case oil drain plug (5) on fitting (6).
NOTE
Let oil drain from water pump gear case oil level check plug until it stops draining; when oil
stops draining, the oil level is correct.
Drain oil into suitable container.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6.
Pour 16 fl. oz. (473 ml) of oil in fill fitting (2).