TM 5-4210-249-13&P-2
0265-1
DRAFT
0265
FIELD LEVEL MAINTENANCE
PRIMER VALVE CABLE REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Both primer valve cables are removed the same way.
Primer valve cable No.1 shown.
1.
Straighten cable wire (1).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Care must be taken when removing cable wire from arm and bracket.
Wire is under
tension and must be held until safely repositioned.
Failure to comply may result in
injury to personnel.
NOTE
Note position of retainer on cable wire prior to removal to ensure proper installation.
2.
Loosen screw (2) and remove retainer (3) from cable wire (1).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT01065
WARNING
ICON 72
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Ties, Cable, Plastic (WP 0625, Item 58)
Lockwasher (2)
References
WP 0615, Fig. 41
Equipment Conditions
Pump operator’s panel manual primer handle
removed (WP 0329)
Pump house panel A opened (WP 0539)