TM 5-4210-249-13&P-2
0139-4
DRAFT
0139
TFFT03740
Step 4.
Remove jumperwire 2768 (white) from GEN PTO ENGAGED indicator terminals.
Check for continuity across wire 2768 (white).
a.
If there is continuity, replace GEN PTO ENGAGED
indicator (WP 0313).
b.
If there is no continuity, repair or replace jumperwire 2768
(TM 9-2320-325-14&P).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION