TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 291 of 1452

TM 5-4210-249-13&P-2
0150-5
DRAFT
0150
TFFT03832
Step 6.
Install fuse FS 6 (WP 0401).
Disconnect cab power distribution wire harness siren
control connector MP2.
Turn battery disconnect switch to ON position (WP 0007).
Put
EMERG MASTER switch to on position (WP 0004).
With a test lead set, check for 22 to
28 VDC between wire 1637 (red) at cab power distribution wire harness siren control
connector MP2, terminal F and a known good ground.
If 22 to 28 VDC are not present, repair wire 1637 in cab power distribution
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
Step 7.
Turn battery disconnect switch to OFF position (WP 0007).
Put EMERG MASTER
switch to off position (WP 0004).
With a test lead set, check for continuity across cab
power distribution wire harness wire 1640 (black) from cab power distribution wire
harness siren control connector MP2, terminal D to a known good ground.
If there is no continuity, repair wire 1640 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top