TM 5-4210-249-13&P-2
0151-4
DRAFT
0151
TFFT03675
Step 4.
Turn battery disconnect switch to OFF position (WP 0007).
Turn Service Drive Lights
Off (TM 9-2320-347-10).
Disconnect cab instrument panel wire harness cab power
distribution wire harness connector.
With a test lead set, check for continuity across
cab instrument panel wire harness wire 1623 (yellow) from cab instrument panel wire
harness EMERG MASTER switch connector, terminal 6 to cab instrument panel wire
harness cab power distribution wire harness connector, terminal 5.
a.
If there is continuity, repair wire 1623 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
b.
If there is no continuity, repair wire 1623 in cab instrument panel wire
harness if repairable (TM 9-2320-325-14&P), or replace cab instrument
panel wire harness (WP 0440).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION