TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 366 of 1452

TM 5-4210-249-13&P-2
0155-4
DRAFT
0155
TFFT04372
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 5.
Put EMERG MASTER, ROOF EMERGENCY LIGHTS, F/R LOWER WARNING, and
SIDE WARNING switches to off position (WP 0004).
Turn Service Drive Lights Off
(TM 9-2320-347-10).
Turn battery disconnect switch to OFF position (WP 0007).
Remove personnel cab instrument panel A (WP 0311).
Remove fuse FS4 from cab
power distribution block (WP 0401).
Check for continuity across terminal connectors on
fuse FS5.
If there is no continuity, replace fuse FS 4 (WP 0401).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top