TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 552 of 1452

TM 5-4210-249-13&P-2
0166-10
DRAFT
0166
TFFT03869
NOTE
24-volt battery charger specifications suggests that charger will attempt to charge
batteries unless battery voltage drops below 10 VDC in a 24 VDC system.
Step 11.
Reconnect batteries (TM 9-2320-325-14&P).
Check for at least 10 VDC across 24 VDC
series connected batteries from 24 VDC main positive terminal to 24 VDC main
negative terminal.
a.
If at least 10 VDC are present, replace 24-volt battery
charger (WP 0359).
b.
If there are less than 10 VDC, replace batteries (WP 0368).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top