TFFT2496
Step 3.
Install lamp in pump operator’s panel DIRECT TANK FILL open indicator (WP 0327).
Open pump operator’s panel housing (WP 0325).
Check for continuity across pump
operator’s panel wire harness wire 3895 (black) from pump operator’s panel DIRECT
TANK FILL open indicator to a known good ground.
If there is no continuity, repair wire 3895 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator’s
panel wire harness (WP 0459).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION