TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 732 of 1452

TM 5-4210-249-13&P-2
0179-2
DRAFT
0179
TFFT03758
NOTE
Make sure that mounting adapter indicator lens is turned fully left (counterclockwise)
before Step 1.
Step 1.
Turn battery disconnect switch to ON position (WP 0007).
Put mounting adapter CB1
switch to ON position (TM 11-5280-890-10).
Check if mounting adapter indicator light
illuminates.
If indicator light does not illuminate, go to Step 3.
NOTE
Mounting adapter indicator light will blink for approximately 3 seconds, then stay lit if
mounting adapter is operating properly.
Step 2.
Put mounting adapter CB1 switch to OFF, then back to ON position
(TM 11-5280-890-10).
Check if mounting adapter indicator continues to blink after
3 seconds.
a.
If mounting adapter indicator light continues to blink after 3 seconds,
notify Supervisor.
b.
If mounting adapter indicator light illuminates and stays continuously
illuminated after 3 seconds, go to Step 7.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top