TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 81 of 1452

TM 5-4210-249-13&P-2
0130-9
DRAFT
0130
TFFT03430
WARNING
ICON 10
Stay clear of equipment (ladder) rack area unless equipment (ladder) rack is locked
in raised position or in fully lowered position with MASTER SWITCH OFF.
Sudden
equipment (ladder) rack movement may cause injury or death to personnel.
CAUTION
Make sure ladders are clear of crew cab.
Ladder could contact crew cab causing
damage to equipment.
NOTE
Continuity should be measured between all terminals when equipment (ladder) rack limit
switch is closed (door switch is not pressed).
Do not disconnect driver side body wire
equipment (ladder) rack limit switch connector for Step 16.
Switch will be back probed for
this procedure.
Step 16.
Unstow equipment (ladder) rack (WP 0011).
Turn Service Drive Lights
Off (TM 9-2320-347-10).
Turn battery disconnect switch to OFF position (WP 0007).
Remove equipment (ladder) rack limit switch (WP 0385).
Check for continuity between
ladder rack limit switch 1165 (Yellow) and a known good ground when switch is closed
(door switch is not pressed).
If there is continuity, go to Step 19.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top