TM 5-4210-249-13&P-3
0312-6
DRAFT
0312
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12. Install cable (23) and wire (22) on stud (24) with locknut (21).
13. Install cable (19) and two wires (18) and (17) on stud (20) with locknut (16).
14. Repair wire H052 (15) (TM 9-2320-325-14&P).
15. Install two wires (12) and (13) on stud (14) with locknut (11).
16. Connect connector (9) on flow meter (10).
17. Connect three connectors (8).
TFFT01624