TM-5-4210-249-13-P-3

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 3 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-3 - Page 285 of 1488

TM 5-4210-249-13&P-3
0363-3/(4 blank)
DRAFT
0363
INSTALLATION
1.
Install auto fill control (10) on power distribution box (11) with four washers (9), lockwashers (8), and
screws (7).
2.
Connect auto fill valve gauge connector (6) to auto fill control connector (5).
3.
Connect auto fill valve connector (4) to auto fill control connector (3).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Close power distribution box cover (2) and tighten two screws (1).
FOLLOW-ON MAINTENANCE
Install pump house panel S (WP 0540)
END OF TASK
END OF WORK PACKAGE
TFFT2529


Back to Top