0366
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Remove battery disconnect switch (8) from battery disconnect box (4).
NOTE
Perform Step (5) if battery disconnect box must be removed.
5.
Remove four nuts (12), screws (13), and battery disconnect box (4) from vehicle.
END OF TASK
INSTALLATION
NOTE
Perform Step (1) if battery disconnect box was removed.
1.
Install battery disconnect box (4) on vehicle with four screws (13) and nuts (12).
2.
Position battery disconnect switch (8) in battery disconnect box (4).
3.
Install nut (11), battery disconnect switch control (10), and screw (9) on battery disconnect switch (8).
4.
Install two cables (7), lockwashers (6), and nuts (5) on battery disconnect switch (8).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
5.
Apply sealant to two cables (7) and battery disconnect switch (8).
TFFT04030
WARNING
ICON 30, 44