TM 5-4210-249-13&P-3
0434-8
DRAFT
0434
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6.
Install green wire (19) on ground stud (20) with lockwasher (18) and nut (17).
7.
Install black wire (15) on overload relay terminal L1 (16) and tighten screw (14).
8.
Install yellow wire (12) on overload relay terminal L2 (13) and tighten screw (11).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
9.
Install control box cover (9) on control box (10) with four screws (8).
TFFT03571
TFFT03570