TM 5-4210-249-13&P-4
0578-1
DRAFT
0578
FIELD LEVEL MAINTENANCE
PUMP COOLER (DUMP-TO-GROUND) VALVE REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
•
Tag and mark air lines and water lines prior to removal to ensure proper installation.
•
Air lines on pump cooler (dump-to-ground) valve remain attached to elbows.
1.
Remove two air lines (1) and (2) and elbows (3) and (4) from pump cooler (dump-to-ground) valve (5).
2.
Remove two fittings (6) and (7) and water lines (8) and (9) from elbows (10) and (11).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00150
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Compound, Sealing, Pipe Thread
(WP 0625, Item 51)
Tags, Identification (WP 0625, Item 51)
Lockwasher (4)
Lockwasher (2)
References
WP 0615, Fig. 113
Equipment Conditions
Water pump engine OFF (WP 0022)
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)
Air system drained (TM 9-2320-347-10)
Water system drained (WP 0041)