TM 5-4210-249-13&P-4
0601-3
DRAFT
0601
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
PTO pump is heavy.
Do not attempt to lift PTO pump without the aid of an assistant.
Failure to comply may result in injury to personnel.
7.
With the aid of an assistant, remove two screws (16), lockwashers (17), washers (18), and PTO pump (15)
from PTO (19).
Discard lockwashers.
8.
Remove hydraulic generator compensator (20) (WP 0584).
9.
Remove fitting (12), fitting (14), and elbow (10) from PTO pump (15).
END OF TASK