TM-5-5420-202-20-1

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 1 OF 4

OCTOBER 1985

  TM-5-5420-202-20-1 - Page 221 of 1020

TM 5-5420-202-20-1
4-30
Change 6
USE OF DIGITAL MULTIMETER
Multimeters AN/URM-105 or ME-77 C/U
pictured throughout this TM are no
longer used.
Use digital multimeter
that is part of your tool set to
troubleshoot the M60A1 AVLB vehicle.
If a troubleshooting procedure reads one of the
following instructions, set your multimeter as
•
“Check if meter indicates continuity”
Use the lowest range on the multimeter
•
“Check if meter indicates a short”
Use the lowest range on the multimeter
•
“Check if meter indicates infinity”
Use the highest range on the multimeter
•
“Set multimeter to OHMS X! scale and zero meter”
Use the lowest range on the multimeter
1


Back to Top