TM-5-5420-202-20-3

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 3 OF 4

OCTOBER 1985

  TM-5-5420-202-20-3 - Page 4 of 1060

TM 5-5420-202-20-3
WARNING
The following summary list is adapted from the warnings
within this volume. However, all warnings should be ob-
served as noted in the text.
Hold up rear drain valve seat when removing last screw attaching valve seat to hull floor.
Valve seat is heavy and can cause injury if it falls.
Hold up front drain valve cage assembly when removing last screw attaching cage to hull.
Valve assembly may fall and cause injury if cage is not held up.
Handle charged fire extinguisher cylinders with care.
Do not jar or subject cylinders to
temperature above 140 degrees F (60 degrees C).
Driver’s hatch cover weighs approximately 130 pounds. Do not try to lift it alone.
The unit commander or senior officer in charge of maintenance personnel assigned to
remove and dispose of contaminated gas filters must prescribe necessary protective clothing
to be worn when replacing gas particulate filters.
He must also prescribe necessary safety
measures to be performed before new gas filters are installed.
Contaminated gas particulate filters must be handled in accordance with FM 3-5 and must
be disposed of by trained personnel.
Compressed air used for cleaning purposes will not exceed 30 psi. Use only with effective
chip guarding and personal protective equipment (goggles/shield, gloves, etc.).
FRH hydraulic fluid may contain Tricresyl Phosphate which, if taken internally, can produce
paralysis. Hydraulic fluid may be absorbed through the skin. Wear long sleeves, gloves,
goggles, and face shield.
If FRH gets in eyes, wash them immediately and get medical aid
immediately.
If FRH gets on skin, thoroughly wash with soap and water. Wash hands
thoroughly prior to eating or smoking.
Application of these measures is considered an
effective control of the hazard.
Dry cleaning solvent P-D-680 is toxic end flammable.
To prevent personal injury, wear
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with
skin, eyes, and clothes and don’t breathe vapors.
Do not use near open flame or excessive
heat. The flash point for Type #1 Dry Cleaning Solvent is 100°F (38°C) and for Type #2 is
137°F (50°C). If you become dizzy while using cleaning solvent, get frest air immediately
and get medical aid.
If contact with eyes is made, wash your eyes with water and get
medical aid immediately.
Remove all jewelry such as rings, watches, dog tags, bracelets, etc.
If jewelry or
disconnected battery ground cable contacts battery terminal, a direct short can result,
causing instant heating of jewelry and tools, severe injury to personnel, or damage to
equipment.
Battery acid (electrolyte) is extremely harmful.
Always wear safety goggles and rubber
gloves, and don’t smoke while servicing batteries.
Severe injury will result if acid contacts
eyes or skin.
Change 6
c


Back to Top