TM-9-1040-267-20-P

LAUNCHER, GRENADE, SMOKE: SCREENING, RP, M243; RP, M257; RP, M259

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

FEBRUARY 1984

  TM-9-1040-267-20-P - Page 29 of 108

LOCATION
ITEM
ACTION
REMARKS
a. Electrical Contacts - Maintenance Instructions.
NOTE
This procedure is used to replace any of four electrical contacts. Replace only as needed to correct
faults.
REMOVAL
CAUTION
To avoid damage to discharger, do not put strain on wires.
1 Discharger Base
a. Screws (1)
Remove eight screws.
b. Cover plate (2) and
Remove from discharger base (4).
gasket (3)
c. Electrical contact
Remove self-locking nut (5) and disconnect termi-
nal (6) from bushing (7).
2-15
TM 9-1040-267-20&P


Back to Top