TM-9-1240-400-34-P

TELESCOPE; PANORAMIC: M115, ELBOW: M139, MOUNT: M138 AND M137

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

OCTOBER 1993

  TM-9-1240-400-34-P - Page 222 of 344

TM 9-1240-400-34&P
5-19.
FINAL INSPECTION INSTRUCTIONS (CONT).
CHECKING M137 TELESCOPE MOUNT CANT CORRECTION
1
Set 500 mils into gunner’s quadrant (1) and place on level bar (2).
2
Rotate handwheel (3) for 500 mil depression.
3
Set 177.8 mils into gunner’s quadrant (1) and place on top surface of cross-leveling fixture (4).
4
Rotate lower handwheel (5), to the right, to 177.8 mil cant angle.
5
Rotate elevation knob (6) and center bubble in cross-level vial (7).
6
Correction counter (8) should read 96.1 ± 0.5 mils.
7
Repeat steps 4 thru 7, checking cant to the left.
8
Repeat steps 4 thru 8 for 800 and 1000 mil elevation.
Connection should be 180.5 + 1.0 mils and 271.9 ± 2.0 mils
respectively.
5-68


Back to Top