2-17.
M115 PANORAMIC TELESCOPE FINAL INSPECTION INSTRUCTIONS (CONT).
SETTING UP AZIMUTH TESTING FIXTURE (CONT)
26
When auto collimation is completed, clamp
adapter fixture (6) securely with three cam locks (8).
27
Recheck auto collimation.
28
Repeat steps 23 thru 27 if required.
29
Remove reflecting mirror assembly (15) from adapter fixture (6).
30
Install frosted glass (17) to eyepiece end of projector collimator (10).