c
3(
1.
Repair orrep!ace “Y” connector
I
Refer to Vol 3, chapter 7,
para 7-1 6
Check lead from truck circuit
breaker to “Y” connector
Put “Y” connector lead back
on contact of heater kit
circuit breaker
Take off truck circuit breaker
to “Y” connector lead at truck
circuit breaker
Put multimeter - lead on a
good ground
Put mulfimeter + lead on
terminal of truck circuit
breaker
Read multimeter. Multimeter should
measure +24 VOI ts DC
Does mu I timeter measure less than +24
volts DC?
/i!!3
““’”’T
/13 REAKER
GO
Figure 25-46 (Sheet 14
of
16)
TA 114561
25-355