TM-9-2320-209-20-2-1

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 2 OF 3; PART 1 OF 2

MAY 1981

  TM-9-2320-209-20-2-1 - Page 632 of 645

TM
9-2320-209-20-2-1
G O
Check voltage through heater
control box
At emergency switch takeoff
Iead from truck circuit breaker
Put multimeter - lead on a
good ground
Put multimeter + lead on contact
of lead from truck circuit breaker
Read mu Itimeter. Mu Itimeter
should measure +24 volts DC
Does mu Itimeter measure +24 volts DC?
GO
FROM TRUCK
CIRCUIT BREAKER
L
EMERGENCY
SWITCH
d
-J
+63
TA 114596
Figure 25-50 (Sheet 10 of 11)
25-390