TM 9-2320-209-20-2-2
●
Put back cable that has come off of
discharge valve
●
●
●
●
●
Make sure valve and control levers
are in OFF positions. Refer to
TM 9-2320-209-10
Using 1/2-inch wrench loosen two
nuts on U-bolt
Slide cable end through U-bolt
and using pliers hold end tightly
Tighten two nuts on U-bolt using
1/2-inch wrench
Adjust cables. Refer to Vol 3,
chapter 18, para 18-25 or
18-27
•
Put back cable that has come off
control lever
●
●
●
●
●
Make sure valve and control lever
are in OFF positions. Refer to
TM 9-2320-209-10
Using 5/8-inch wrench loosen nut
Slide cable end through clamp
bolt and using pliers hold end
tightly
Tighten nut using 5/8-inch wrench
Adjust cables. Refer to Vol 3,
chapter 18, para 18-25 or 18-27
Ž
Replace broken discharge valve control
cable
●
Refer to Vol 3, chapter 18, para
18-25 or 18-27
Figure 65-5 (Sheet 2 of 3)
TA 114978
65-17