TM 9-2320-209-20-3-1
FRAME 2
1.
2.
3.
4.
GO
Take off
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
protective cover from hole in tank. Clean mating flanqes of fuel
pump and tank with dry cleaning solvent. Apply thin coat of sealer com-
pound to threads of fuel fittings before assembling.
Put new
Put fuel
gasket (1) on fuel tank (2) and aline 10 holes.
CAUTION
Be very careful when putting fuel pump in tank so that
electrical cable shield will not scrape hole. Damage to
the shield could cause electrical failure.
pump (3) in tank (2) as shown.
Aline holes in pump with holes
-
in gasket (l) and tank (2) .
Using screwdriver, screw in and tighten 10 screws (4) with 10 lockwashers
(5) through holes in pump mounting flange.
TO FRAME 3
TA 047132
4-49