b. Replacement.
FRAME 1
1.
2.
3.
4.
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
Using solvent, clean all parts.
Put preformed packing (1) in place in groove on rod and cap
Put filter element (3) in place on rod and cap assembly (2).
gasket (5), and flat washer (6) on threaded end of rod.
assembly (2).
Put retainer (4),
Using torque wrench, screw on and tighten nut (7) to 5 pound-feet.