17-36. CIRCUIT BREAKER BOX ASSEMBLY REMOVAL, REPAIR, AND REPLACEMENT.
TOOLS: No special tools required
SUPPLIES: Solvent, dry cleaning, type II (SD-2), Fed. Spec P-D-680
Clean rags
Emery cloth
PERSONNEL: One
EQUIPMENT CONDITION:
Truck parked, engine off, hand brake set.
WARNING
Disconnect all external supply cables before working
on circuit breaker box. Electric current can cause
injury to personnel and damage to equipment.
Preliminary Procedure.
Disconnect external power supply cables. Refer
to TM 9-2320-209-10.
17-387