TM 9-2320-209-34-2-2
FRAME 3
1.
2.
3.
4.
5.
Put on all wires (1) in power switch box (2) as tagged.
Take off tags. Pull three wires (3) through nipple and bushing in power
switch box (2) as tagged. Take off tags.
Connect three wires (3) to STOP and START switch (4) as tagged. Take
off tags.
Close power switch door (5).
Put on STOP and START switch cover (6) and put in two screws (7).
NOTE
Follow-on Maintenance Action Required:
1.
Replace circuit breaker box. Refer to para 17-36.
2.
Replace dome light switch. Refer to
TM 9-2320-209-20.
3.
Replace converter. Refer to para 17-37.
END OF TASK