Table 2-4. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 5. Set multimeter to RX1 scale.
Step 6. Touch negative lead of multimeter to frame ground.
Step 7. Touch positive lead of multimeter to contact end of lead 28 at fuel gage. Continuity
should be present.
a. If continuity is present, reconnect wires and recheck fuel gage operation.
b. Repair or replace wiring if continuity is not present (para. 4-52).