6-3. WATER MANIFOLD MAINTENANCE (Contd)
6. Install water temperature sending unit (12) on front manifold (9).
7. Install adapter (19), adapter (20), and draincock (2) on rear manifold (18).
1. Install six new gaskets (17), rear manifold (18), center manifold (14), and front manifold (9) on
cylinder head (15) with twelve new screw-assembled lockwashers (10).
2. Connect water temperature sending unit wire (13) to water temperature sending unit (12),
3. Position clamp (1) on heater hose (16).
4. Connect heater hose (16) to draincock (2). Tighten clamp (1).
FOLLOW-ON TASKS: “ Install surge tank (TM 9-2320-260-20).
“ Install thermostat housing (TM 9-2320-260-20).
6-5