ABS - CODE SLW 43 (RIGHT SIDE - YELLOW CHANNEL) - Continued
CONDITION/INDICATION
IS MODULATOR VALVE FAULTY?
DECISION
YES - Replace rear relay valve (Volume 3, WP
0457). Go to Step (6) to verify problem is solved.
YES - Go to Step (4).
STEP
4.
IS PRIMARY AIR SYSTEM OPERATING PROPERLY?
Check for a primary air system fault. Refer to point to point schematics.
CONDITION/INDICATION
IS PRIMARY AIR SYSTEM OPERATING PROPERLY?
DECISION
NO - Perform semi-annual PMCS on air lines and brake chambers (WP
0207).
YES - Go to Step (6) to verify problem is solved.
STEP
5.
ARE BRAKES IN PROPER ADJUSTMENT AND WORKING ORDER?
Check brakes for mechanical or adjustment problems (Volume 3, WP
0432).
CONDITION/INDICATION
ARE BRAKES IN PROPER ADJUSTMENT AND WORKING ORDER?
DECISION
NO - Repair or adjust brakes as needed (Volume 3, WP
0432). Go to Step (6) to verify problem is solved.
YES - Notify supervisor. It is possible another troubleshooting work package applies.
TM 9-2320-272-23-2
0169
0169-5