G04: CHARGING CIRCUIT AND BATTERY VOLTAGE TEST - Continued
STEP
2.
Generator operation.
a.
Check generator indicator for normal reading.
b.
Turn headlights and accessories off (TM 9-2320-272-10).
c.
Shut off engine (TM 9-2320-272-10).
CONDITION/INDICATION
Does generator indicator gauge read normal?
DECISION
YES - Perform G05: Engine Warmup/Coolant Check/Oil Pressure Test (WP
0192).
NO - Perform Battery/Alternator Gauge Inoperative troubleshooting (Volume 1, WP
0108).
STEP
3.
Battery voltage.
Check battery voltage.
CONDITION/INDICATION
Is battery voltage low?
DECISION
YES - Go to Step (4).
NO - If voltage is high, replace alternator M939/A1 60 amp (WP
0300),
M939A2 60 amp (WP
0301), 100 amp (Volume 5, WP
0780). After repairs are complete rerun GO-chain test
to verify problem is fixed.
STEP
4.
Battery voltage test.
a.
Battery voltage low.
b.
Allow vehicle to run 5 minutes and watch display.
c.
If voltage is not within limits, turn headlights and accessories off (TM 9-2320-272-10).
d.
If voltage is not within limits, shut off engine (TM 9-2320-272-10).
CONDITION/INDICATION
Is battery voltage within limits?
DECISION
YES - Go to Step (5).
NO - Perform NG50: Charging Circuit Test (WP
0201).
TM 9-2320-272-23-2
0191
0191-2