FIELD MAINTENANCE
NG90: GOVERNOR/POWER TEST FAULT ISOLATION
INITIAL SETUP:
Personnel Required
(2)
References
TM 9-2320-272-10
TM 9-4910-571-12&P
References (cont.)
WP
0193
WP
0195
WP
0205
WP
0245
WP
0246
TROUBLESHOOTING PROCEDURE
NG90: GOVERNOR/POWER TEST FAULT ISOLATION
STEP
1.
Perform G06: Power Test.
CAUTION
Check that air inlet, is clear of tools, debris, dirt, and dust before performing test.
a.
Remove air cleaner from intake housing (WP
0246).
b.
Repeat G06: Power Test Step (2) (WP
0193).
CONDITION/INDICATION
Does engine pass power test with air cleaner out?
DECISION
YES - Replace air filter
(WP
0246). After completing repair, rerun GO-Chain tests to verify problem is fixed and
no other problems exists.
NO - Go to Step (2).
TM 9-2320-272-23-2
0204
0204-1