INSTALLATION
CAUTION
Ensure plugs or covers are completely removed from all hoses and connections. Failure to
do this may result in transmission and oil cooler damage.
NOTE
Male pipe threads must be wrapped with antiseize tape before installation.
1.
Install elbow (Figure 5, Item 1) on housing (Figure 5, Item 2).
2.
Connect return hose (Figure 5, Item 11) to elbow (Figure 5, Item 1).
3.
Install elbow (Figure 5, Item 3) on housing (Figure 5, Item 2).
4.
Connect supply hose (Figure 5, Item 4) to elbow (Figure 5, Item 3).
5.
Install o-ring (Figure 5, Item 6) and elbow (Figure 5, Item 5) in oil cooler (Figure 5, Item 8).
6.
Connect supply hose (Figure 5, Item 4) to elbow (Figure 5, Item 5).
7.
Install o-ring (Figure 5, Item 9) and elbow (Figure 5, Item 10) in oil cooler (Figure 5, Item 8).
8.
Connect oil cooler supply hose (Figure 5, Item 7) to elbow (Figure 5, Item 10).