REMOVAL
WARNING
Do not disconnect air lines or hoses before draining air reservoirs. Small parts under pressure
may shoot out with high velocity. Failure to comply may result in injury or death to personnel.
NOTE
Tag air lines for installation.
1.
Disconnect two air lines (Figure 1, Item 9) from elbows (Figure 1, Item 8).
2.
Remove two elbows (Figure 1, Item 8) from air supply valve (Figure 1, Item 10).
3.
Remove pin (Figure 1, Item 3) from button (Figure 1, Item 4).
4.
Remove button (Figure 1, Item 4), nut (Figure 1, Item 5), and air supply valve (Figure 1, Item 10) from mounting
bracket (Figure 1, Item 6).
5.
Remove two locknuts (Figure 1, Item 2), screws (Figure 1, Item 7), and mounting bracket (Figure 1, Item 6)
from instrument panel (Figure 1, Item 1). Discard locknuts.
TM 9-2320-272-23-5
0779
0779-2