TM 9-2320-272-24-4
5-18. FUEL PUMP SETUP AND CALIBRATION (Contd)
n. Shutdown and Removal from Test Stand
1.
Depress test stand stop button (11).
2.
Place test stand fuel heat switch (10) in OFF position.
3.
Close test stand fuel pressure control valve (12) and fuel flow control valve (17).
4.
Remove 1/4 in. (6.35 mm) flexible hose (13) from small fitting (9) on fuel pump (3) and auxiliary
return fitting (16) on test stand (2).
5.
Remove leakage accumulator hose (15) from No. 1 accumulator can (14) and stand leak test
connector (17).
5-119