TM 9-2320-273-20
Item
No.
37
38
39
Table
Interval
Annual
Annual
Annual
or On
Condi-
tion
1-1. Unit Level Preventive Maintenance Checks And Service
Item To B
Inspected
Engine
Throttle
Lever
Head-
lights
Hydraulic
System
(M916
and
M920)
Procedure
Lubricate with GAA the engine throttle
lever pivot.
Check headlight adjustment. Adjust head-
lights (paragraph 5-25.1).
NOTE
If AOAP laboratory is not available, drain
and refill hydraulic reservoir every 6,000
miles (9,654 km) or annually, whichever
comes first.
a. Replace hydraulic fluid filters (all mod-
els paragraph 12-9).
NOTE
To drain hydraulic reservoir, remove bot-
tom drain plug.
b. Drain reservoir using drain plug.
c. Refill hydraulic reservoir using OE/
HDO.
d. Inspect PTO Hydraulic pump for leaks
or obvious damage.
M915-M920
Not Mission
Capable If:
Fitting will not purge
old lubricant out of
component.
“Do not operate” re-
ceived from AOAP
laboratory.
b. AOAP indicates
changes required.
3-10.18 Change 4