2-l5. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 2-9. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
Step 4.
Turn
engine start switch to ON position, turn PTO ENGAGE switch ON and OFF several
times while touching PTO solenoid to feel for vibration (listen for clicking).
If
PTO solenoid valve vibrates (clicks), refer to Step 6.
If solenoid does not click, go to Step 5.
Step 5.
Check solenoid wires for loose connections, damage, and continuity.
Tighten loose connections, repair damaged wires and replace wires with no
continuity.
If all wires and connections are okay, replace PTO solenoid (para 7-30).
Step 6.
If PTO still will not engage, refer to Hydraulic System Troubleshooting (page 2-153).
Step 7.
Deleted.
Step 8.
Deleted.