Troubleshooting Malfunctions (Cont)
Table 2-9. Troubleshooting (Cont)
EVACUATE HOSES
The purpose of this operation is to remove the unused fuel from the hose reels. To do this the basic
pumping operation is used except the V6 (Fuel/Defuel Valve) is put in the defuel position. This routes fuel
flow to the ED (Eductor) instead of through the flowmeter. Flow through the ED (Eductor) draws the fuel
from the hose reels and then both flow back to the tank through valve V9 (Check Valve).
NOTE
Refer to Figure 2-11 for tanker component identification.
Figure 2-13. Tanker Operation Functional Diagram (Sheet 6 of 12).
2-217