TM-9-2320-279-20-1

M977 SERIES, 8x8 HEAVY EXPANDED MOBILITY TACTICAL TRUCKS (HEMTT)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; ORGANIZATIONAL MAINTENANCE, VOLUME 1 OF 3

  TM-9-2320-279-20-1 - Page 652 of 985

TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
a. Removal.
(1)
Pull light socket (1) from
water temperature gage (2).
NOTE
Tag mark wires before
disconnecting.
(2)
(3)
(4)
(5)
Disconnect two wires (3)
from terminals (4).
Remove two nuts (5),
lockwashers (6), and
bracket (7).
Pull water temperature
gage (2) from instrument
panel (8).
Remove three nuts (9),
lockwashers (10), and three
terminals (4) from water
temperature gage (2).
b. Installation.
(1)
(2)
(3)
(4)
(5)
Install three terminals (4),
three lockwashers (10), and
nuts (9) on water
temperature gage (2).
Install water temperature
gage (2) and bracket (7) in
instrument panel (8).
Install two nuts (5) and
lockwashers (6) to secure
water temperature gage (2)
and bracket (7) on instrument panel (8).
Connect two wires (3) to water temperature gage (2).
Push light socket (1) into back of water temperature gage (2).
c. Follow-on Maintenance.
(1)
Install instrument panel (para 7-19).
(2)
Start engine and check operation of water temperature gage (TM 9-2320-279-10).
(3)
Shut off engine (TM 9-2320-279-10).
END OF TASK
7-83