TM-9-2320-279-20-1

M977 SERIES, 8x8 HEAVY EXPANDED MOBILITY TACTICAL TRUCKS (HEMTT)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; ORGANIZATIONAL MAINTENANCE, VOLUME 1 OF 3

  TM-9-2320-279-20-1 - Page 895 of 985

TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
7-87. TANK LEVEL lNDICATOR ADJUSTER REMOVAL/lNSTALLATlON/ADJUSTMENT (M978)
(CONT).
(3)
Connect batteries (para 7-91).
(4)
Load tanker with fuel (TM 9-2320-279-10).
(5)
Soldier A sets TLI TANK LEVEL INDICATOR switch (3) on and watches TLI TANK LEVEL
INDICATOR gage (4) while Soldier B turns screw (5). When TLI TANK LEVEL INDICATOR
gage (4) needle indicates FULL, Soldier A tells Soldier B to stop turning screw (5).
(6)
Set TLI TANK LEVEL INDICATOR switch (3) off.
(7)
Install cap (1) on tank level indicator adjuster (2).
7-317