TM 9-2320-279-20-3
M978 Tanker Maintenance Instructions (COnt)
25-30. V17 GRAVITY VALVE REMOVAL/INSTALLATION (CONT).
a. Removal.
(1)
Push MC MANUAL
CONTROL EM VALVE
lever (1) full forward and
down in closed position.
WARNING
Contact with fuel can irritate
eyes and skin. Do not let fuel
get into eyes. If fuel comes
into contact with eyes,
immediately rinse eyes with
clear water. Wash fuel off skin
with soap and water as soon
as possible after contact.
(2)
(3)
(4)
(5)
(6)
Remove dust cap (2) from
adapter (3).
Move handle (4) to OPEN
position.
When fuel stops draining,
close handle (4), hold
adapter (3) in place, and
remove two nuts (5),
screws (6), and coupling
halves (7).
Remove adapter (3).
Remove coupling gasket (8).
25-138